Balance Automatic Control System Load 3 Phase

Doringin, Fanny and Budiman, Marson James and Walukow, Stephy (2019) Balance Automatic Control System Load 3 Phase. International Journal of Computer Application, 177 (9). pp. 33-37. ISSN 0975-8887

[img] Text
doringin-2019-ijca-919472.pdf

Download (702kB)
Official URL: https://www.ijcaonline.org/archives/volume177/numb...

Abstract

All electrical energy is generated, transmitted, and distributed in the form of a three-phase system. Ideally, the perceived stress of the equipment is a three-phase voltage with a sinusoidal and balanced shape. However, the unbalanced loading and impedance of the line impedance causes the voltage felt by the equipment to become unbalanced. For large power consumers, such as educational institutions,s hotels, offices, shopping centers, industries, etc. are connected with 3 phase electricity (phase R, S and T). In the planning and installation of electrical installations by installers (Electrical Experts) it is always planned that the load connected to the R, S and T phases is attempted evenly (equally), but in operation (ON / OFF) electricity is not always evenly distributed in each phase, so it occurs unbalanced load between phases. As a result of unbalanced load between phases causes electrical power losses. The purpose of this study is to test the intelligence of the control of the balance of the three-phase electrical load and compare the unbalanced load current with the load current after being balanced. The results obtained are in the form of a prototype control of the three-phase electric load balance, which can control unbalanced and balanced currents on the input side sensor as well as the voltage on the sensor output side. From the results of testing the current at unbalanced load with the current after being balanced, obtained phase unbalanced phase data R = 4.43, S phase = 1,162 phase T = 3.18 after being balanced by the system to R = 2.78, phase S = 3.27 phase T = 3.27, from the results of measurements and calculations in theory the average percentage error is obtained for each current test in phase R, S, T = 0.01 A

Item Type: Article
Subjects: K Electrics (Kelistrikan) > KD Karya Ilmiah
L Computer and Hardware > LD Karya Ilmiah
Divisions: Teknik > Jurusan Teknik Elektro
Depositing User: Samuel Johannes
Date Deposited: 09 Aug 2020 17:57
Last Modified: 09 Aug 2020 17:57
URI: http://repository.polimdo.ac.id/id/eprint/2050

Actions (login required)

View Item View Item